Skip to content

Complaint guide · Air Conditioner

LG Air Conditioner Complaints

An air conditioner can disappoint in several distinct ways: it runs but the room stays warm, it cools well and then stops, it drips onto the wall, or it makes a noise that was not there last summer. Each pattern narrows the fault to a different part of the system — airflow, drainage, electrical starting components, sensors or the refrigerant circuit.

This page describes the LG air conditioner complaints we see across Bengaluru, Hosur and Chennai, the warning signs that mean stop using the unit, the causes a technician tests and the repairs that follow. Refrigerant handling, outdoor-unit electrical work and compressor replacement are strictly technician work.

Direct answer

Why is my LG air conditioner running but not cooling the room?

The most common reason is restricted airflow from clogged filters or a dirty indoor coil. If airflow is healthy, the next checks are the outdoor unit, the starting capacitor, the sensors and finally the refrigerant charge and pressures.

Air Conditioner troubleshooting guide

What customers report

Common LG air conditioner complaints

01

Unit runs but the room does not cool

Air comes out of the indoor unit but it is not cold, or the room cools only slightly before warming again.

02

Water dripping from the indoor unit

Water runs down the wall, drips from the louver area or collects in the room instead of leaving through the drain.

03

Ice forming on the indoor coil or pipes

Frost appears on the indoor unit, on the copper lines or around the outdoor valves.

04

Outdoor unit not starting or stopping immediately

The indoor fan runs but the outdoor unit stays silent, hums briefly, or starts and trips within seconds.

05

Unpleasant smell when the AC starts

A damp, musty or sour smell comes from the indoor unit, strongest in the first minutes of operation.

06

Rattling, buzzing or squealing noise

Noise comes from the indoor fan, the outdoor fan, the casing or the compressor area.

Symptoms and warning signs

These signs mean the appliance should stop being used until it has been checked.

  • The unit trips the circuit breaker or the dedicated AC switch.
  • A burning smell, smoke or scorch marks appear at the indoor or outdoor unit.
  • Water is dripping near electrical wiring, a socket or the indoor PCB cover.
  • The outdoor unit hums loudly without starting, then the breaker trips.
  • Ice covers the indoor coil and the unit keeps running.
  • The outdoor unit makes a metallic knocking sound while running.

Possible causes a technician will test

  • Filters and the indoor coil clogged with dust, pollen and road grit, reducing heat exchange.
  • A blocked condensate drain line or a drain tray that has shifted, causing water to overflow indoors.
  • A failed starting capacitor, which leaves the outdoor fan or compressor unable to start.
  • Low refrigerant from a leak at a flare joint, valve or coil, confirmed by pressure testing.
  • A dirty outdoor condenser coil or an outdoor unit with no clearance for airflow.
  • A faulty indoor or outdoor fan motor, or a fan blade obstructed by debris.
  • Sensor or PCB faults that misread room or coil temperature and stop cooling early.
  • A compressor that has failed electrically or mechanically, usually after repeated start faults.
  • Voltage fluctuation or an undersized supply circuit, common on shared lines and in older buildings.

Error indications to note

If the display shows a code, note it before switching the appliance off. A code narrows the fault but does not replace testing.

Error indications for air conditioner complaints
IndicationWhat it points to
CH-series code on the displayA communication or sensor indication between the indoor and outdoor units. Wiring, connectors and sensors are checked before boards are replaced.
Display flashes and the unit stopsThe control has detected an abnormal condition and shut down for protection. The stored indication is read during diagnosis rather than guessed from the flash count.
Unit restarts on its ownOften a supply or protection issue rather than a cooling fault. Voltage, the outdoor unit's start components and the PCB are checked.
No display but the beep is heardThe indoor control has power but the display or its connection has failed. This is a low-risk electrical check for a technician.

How the complaint is diagnosed

  1. 1The complaint is reproduced with the remote set to a known mode, temperature and fan speed.
  2. 2Filters, indoor coil and blower are inspected for airflow restriction.
  3. 3The outdoor unit is observed for fan and compressor start behaviour, and the capacitor is tested.
  4. 4Refrigerant pressures and line temperatures are measured only after airflow and electrical checks.
  5. 5The condensate drain is flushed and the tray checked for slope and blockage.
  6. 6The estimate separates cleaning, electrical parts and any refrigerant work so you can decide clearly.

LG air conditioner repair options

  • Filter clean, indoor coil clean and blower clean to restore airflow.
  • Condensate drain flush and drain tray repositioning for indoor water leaks.
  • Starting capacitor replacement for an outdoor unit that will not start.
  • Fan motor replacement where the indoor or outdoor fan has seized or become noisy.
  • PCB or sensor replacement for control and communication faults.
  • Leak repair and refrigerant recharge after pressure testing, where a leak is confirmed.
  • Compressor replacement only when electrical and mechanical tests show it has failed.

When professional repair is required

  • The unit trips the breaker, smokes or smells of burning.
  • Water is leaking near wiring or the indoor control cover.
  • Ice forms on the indoor coil or refrigerant lines.
  • The outdoor unit hums but does not start.
  • Cooling has dropped noticeably after filters were cleaned.
  • You suspect a refrigerant leak and the unit has been topped up before.

Safety first

  • Switch the unit off at the remote and the isolator before cleaning filters.
  • Do not open the outdoor unit, the indoor PCB cover or the electrical box.
  • Never handle refrigerant, gauges or copper lines yourself.
  • Do not keep resetting the breaker on a unit that trips it.
  • Do not block the indoor outlet or the outdoor unit's airflow clearance.
  • Do not use water to clean electrical parts or the indoor control area.

Keep going

The other air conditioner guide

Use the troubleshooting guide to run the safe customer checks before a visit, and to know which symptoms mean stop.

Book the right visit

Air Conditioner service and repair in three cities

The same diagnosis process applies across our LG appliance serving areas. Use a city page for local coverage, or book directly and choose your city in the form.

See all air conditioner repairs

Not affiliated with, endorsed by or authorised by LG Electronics. LG Digital Expert is an appliance repair business and is not an LG service centre.

Air Conditioner · complaints

Air Conditioner complaint questions

Direct answers about the symptoms, the safe checks and the point at which a technician should take over.

Still unsure? Contact our team or book a diagnosis.

Why does my AC run but blow only slightly cold air?

Restricted airflow is the most common cause: clogged filters, a dusty indoor coil or a blower that cannot move air. If airflow is correct, the outdoor unit, capacitor, sensors and refrigerant charge are checked in that order. Cleaning alone often restores cooling when the fault is airflow.

Water is dripping from my indoor unit. Can I keep using it?

Stop using it if the water is anywhere near wiring, a socket or the control cover. A blocked drain line or a shifted tray is the usual cause, but water inside the casing can reach electrical parts. Switch it off and book a visit rather than running it overnight.

Does ice on the indoor coil mean the gas is low?

It can, but it can also come from restricted airflow or a sensor fault. Low refrigerant causes the coil to run below freezing, while a dirty coil or a failing blower reduces heat exchange and produces the same frost. Pressures and airflow are both checked before any gas decision.

The outdoor unit hums and then stops. What is happening?

That pattern usually points to a starting capacitor, a seized fan motor or a supply problem rather than the compressor itself. The capacitor and fan are tested first. Continuing to restart the unit can damage the compressor, so switch it off at the isolator and book a diagnosis.

Why does the AC smell musty when it starts?

Moisture and dust on the indoor coil, blower and drain tray create a damp environment where mould and bacteria grow. A coil and blower clean plus a drain flush removes the source. Masking the smell with fragrance does not fix it and can make the air quality worse.

How is an air conditioner complaint diagnosed?

The technician checks operating mode and settings, inspects and cleans the airflow path, observes the outdoor unit start, tests the capacitor and measures pressures and line temperatures. You then receive a written estimate covering the specific fault before any repair or recharge is carried out.

Complaint diagnosis

Let a technician diagnose the air conditioner.