Skip to content

Complaint guide · Refrigerator

LG Refrigerator Complaints

A refrigerator complaint is rarely just “not cooling”. The pattern matters: whether the freezer still works, whether the compressor runs continuously, whether ice forms on one side of the cabinet, and whether water appears inside or underneath. Those details decide whether the fault sits in airflow, defrosting, sealing or the sealed cooling system.

This page covers the complaints we are called for most often on LG refrigerators, the causes worth testing first, the indications the display can show and the point at which a customer should stop and book a technician. Refrigerant work and sealed-system repairs are never customer tasks.

Direct answer

Why is my LG refrigerator running but not cooling?

The most common causes are restricted airflow from a dusty condenser or blocked vents, a door gasket that no longer seals, a defrost fault that ices the evaporator, or a failing evaporator fan. A refrigerant leak is possible but is confirmed only after those checks.

Refrigerator troubleshooting guide

What customers report

Common LG refrigerator complaints

01

Refrigerator compartment warm while the freezer is cold

The freezer holds temperature but milk and vegetables spoil. Usually airflow, a damper or a defrost problem rather than a total cooling failure.

02

Both compartments losing temperature

The compressor may be running without cooling, running briefly and clicking off, or not running at all.

03

Water pooling inside or under the cabinet

Water appears in the vegetable drawer area, below the crisper or on the floor beneath the door.

04

Ice build-up on the back wall or freezer floor

Frost thickens on the evaporator cover or around the freezer drawer, reducing space and cooling performance.

05

Refrigerator runs constantly or clicks repeatedly

The compressor never seems to rest, or it starts with a click and stops within seconds.

06

Noisy fan, gurgling or vibration

A rubbing or buzzing fan noise, a rattling cabinet or a gurgle that continues after the compressor stops.

Symptoms and warning signs

These signs mean the appliance should stop being used until it has been checked.

  • The cabinet is warm while the compressor is hot to the touch and running continuously.
  • The compressor clicks and stops every few minutes instead of running.
  • Water is collecting near the refrigerator's electrical connection or the socket.
  • A burnt smell or scorched plug is noticed at the wall socket.
  • Frost covers most of the evaporator and the fan begins to rub against ice.
  • The door does not close flush, or condensation forms along the gasket.

Possible causes a technician will test

  • A condenser coil packed with dust, restricting heat release and forcing longer run times.
  • Blocked air vents or an overloaded cabinet that stops cold air reaching the fridge section.
  • A hardened or torn door gasket that lets warm, humid air into the cabinet.
  • A failed defrost heater, defrost sensor or timer that leaves ice on the evaporator.
  • An evaporator fan motor that has slowed, seized or is rubbing on ice.
  • A failed start relay or run capacitor, which prevents the compressor from starting.
  • A damper that no longer opens between the freezer and fridge compartments.
  • A temperature sensor or control-board fault giving a false reading.
  • A refrigerant leak or restriction in the sealed system, confirmed by pressure testing.

Error indications to note

If the display shows a code, note it before switching the appliance off. A code narrows the fault but does not replace testing.

Error indications for refrigerator complaints
IndicationWhat it points to
Er FFA freezer fan fault indication: the freezer fan is not responding as expected. Ice build-up and the fan motor are checked.
Er rFA refrigerator fan fault indication: the fridge-side fan circuit is tested along with the damper and airflow path.
Er FS / Er RSSensor indications for the freezer or refrigerator side. The sensor and its wiring are tested before the board is suspected.
Er dSA defrost sensor indication: the defrost circuit is checked for a failed heater, sensor or control output.
Blinking temperature displayThe control is reporting that the cabinet has not reached its target. It is a symptom, not a diagnosis, and needs the cooling checks below.

How the complaint is diagnosed

  1. 1The actual cabinet and freezer temperatures are measured, not just read from the display.
  2. 2The compressor is observed for start attempts, current draw and whether it runs continuously.
  3. 3The condenser is inspected for dust and the fan for obstruction and airflow.
  4. 4The door gasket is checked with a paper test and a visual inspection for hardening or tears.
  5. 5The evaporator cover is opened to look for ice patterns that point to a defrost fault.
  6. 6Fan operation, damper movement and sensor readings are checked before any sealed-system conclusion.

LG refrigerator repair options

  • Condenser clean, vent clearance and load reorganisation to restore airflow.
  • Door gasket replacement where the seal no longer closes evenly.
  • Defrost heater, sensor or control replacement for an iced evaporator.
  • Evaporator or condenser fan motor replacement for noise or lost airflow.
  • Start relay and run capacitor replacement for a compressor that clicks but does not start.
  • Damper replacement when the fridge section cannot receive cold air.
  • Leak detection and sealed-system repair where pressures confirm a refrigerant fault; this is specialist work.

When professional repair is required

  • The freezer and fridge are both warming and food safety is at risk.
  • The compressor clicks repeatedly, runs hot or does not start.
  • There is ice on the evaporator or the fan is rubbing against frost.
  • Water is leaking inside the cabinet or onto the floor.
  • The machine trips the breaker or the plug or socket shows heat damage.
  • The refrigerator has been moved, tipped or stored and now will not cool.

Safety first

  • Do not puncture, cut or attempt to recharge the sealed refrigerant circuit.
  • Unplug the refrigerator before cleaning the condenser or moving it.
  • Do not chip ice off the evaporator with a knife or screwdriver.
  • Keep the refrigerator clear of the wall so the condenser can release heat.
  • Do not use an extension board that is already loaded with other appliances.
  • Discard food that has been above safe temperature rather than refreezing it.

Keep going

The other refrigerator guide

Use the troubleshooting guide to run the safe customer checks before a visit, and to know which symptoms mean stop.

Book the right visit

Refrigerator service and repair in three cities

The same diagnosis process applies across our LG appliance serving areas. Use a city page for local coverage, or book directly and choose your city in the form.

See all refrigerator repairs

Not affiliated with, endorsed by or authorised by LG Electronics. LG Digital Expert is an appliance repair business and is not an LG service centre.

Refrigerator · complaints

Refrigerator complaint questions

Direct answers about the symptoms, the safe checks and the point at which a technician should take over.

Still unsure? Contact our team or book a diagnosis.

Why is the freezer cold but the refrigerator section warm?

That pattern usually points to airflow rather than a total gas failure. Blocked vents, an overloaded cabinet, a failed evaporator fan or a damper that will not open are the first checks. A defrost fault that ices the evaporator can produce the same symptom, so the ice pattern is inspected too.

Does a warm refrigerator always mean low gas?

No. Low refrigerant is one possibility among several and should not be assumed from the temperature alone. Dust-packed condensers, door-seal leaks, fan faults, defrost faults and sensor errors are all more common and are tested first. A sealed-system conclusion requires pressure testing.

The compressor clicks and stops. Is it finished?

Not necessarily. A failing start relay or run capacitor can produce exactly that click-and-stop behaviour while the compressor itself is still serviceable. The start circuit is tested before a compressor is condemned, and only then is replacement discussed.

How often should the condenser be cleaned?

In dusty or coastal areas, every six to twelve months is a sensible routine; Bengaluru and Chennai installations often need it more often than an inland home with filtered air. Cleaning is a simple unplug-and-brush job at the back or base, and it noticeably reduces running time.

Can I use the refrigerator while waiting for a repair?

If both compartments are holding safe temperatures, short-term use is fine. If the cabinet is warm, move perishable food to another refrigerator or a cooler. Repeatedly opening a warm refrigerator makes the compressor work harder and does not fix the fault.

What happens during a refrigerator repair visit?

The technician measures temperatures, observes the compressor start, inspects the condenser and gasket, checks the evaporator for ice and tests fans, sensors and the defrost circuit. You receive a written estimate before any part is replaced, and sealed-system work is explained separately because it takes longer.

Complaint diagnosis

Let a technician diagnose the refrigerator.

Choose your appliance, city and preferred slot. You see a written estimate before any repair begins.

What you can expect

  • Diagnosis charge quoted before the visit
  • Written estimate before any repair
  • Service note after the work is done

Not affiliated with, endorsed by or authorised by LG Electronics.